POWER ONE 1000 TPE 1kV.Power cable for the cable carrier.
Unshielded TPE power cable for the cable carrier, up to 10 million motion cycles and travel lengths up to 1000 m. 15 variants, from 1x2.5 mm² to 1x300 mm².
Class 1000: extreem. The highest number of cycles and the longest travel lengths, TPE sheath.
Schematic cross-section.
- Cable type
- Power cables
- Sheath
- TPE
- Shielding
- Unshielded
- Flexibility
- Highly flexible
- Motion cycles
- up to 10 million
- Travel length
- up to 1,000 m
- Assembly
- Single
- Voltage
- 1 kV
- Outer diameter
- 6,2–34,4 mm
Variants
15 variants
Cores and cross-section, article number, outer diameter and weight. Add the cables you need to your request; you get a price and delivery time per cable.
1x2,5 mm²
49581- Outer Ø
- 6,2 mm
- Weight
- 0,054 kg/m
- Min. Hi
- 7 mm
1x4 mm²
49582- Outer Ø
- 6,8 mm
- Weight
- 0,074 kg/m
- Min. Hi
- 8 mm
1x6 mm²
49583- Outer Ø
- 7,4 mm
- Weight
- 0,096 kg/m
- Min. Hi
- 9 mm
1x10 mm²
49584- Outer Ø
- 8,6 mm
- Weight
- 0,145 kg/m
- Min. Hi
- 10 mm
1x16 mm²
49585- Outer Ø
- 9,7 mm
- Weight
- 0,207 kg/m
- Min. Hi
- 11 mm
1x25 mm²
49586- Outer Ø
- 11,3 mm
- Weight
- 0,303 kg/m
- Min. Hi
- 13 mm
1x35 mm²
49587- Outer Ø
- 12,7 mm
- Weight
- 0,404 kg/m
- Min. Hi
- 14 mm
1x50 mm²
49588- Outer Ø
- 15 mm
- Weight
- 0,58 kg/m
- Min. Hi
- 17 mm
1x70 mm²
49589- Outer Ø
- 17 mm
- Weight
- 0,796 kg/m
- Min. Hi
- 19 mm
1x95 mm²
49590- Outer Ø
- 19,5 mm
- Weight
- 1,042 kg/m
- Min. Hi
- 22 mm
1x120 mm²
49591- Outer Ø
- 21,4 mm
- Weight
- 1,268 kg/m
- Min. Hi
- 24 mm
1x150 mm²
49592- Outer Ø
- 24,2 mm
- Weight
- 1,595 kg/m
- Min. Hi
- 27 mm
1x185 mm²
49593- Outer Ø
- 26,6 mm
- Weight
- 1,949 kg/m
- Min. Hi
- 30 mm
1x240 mm²
49594- Outer Ø
- 30,2 mm
- Weight
- 2,537 kg/m
- Min. Hi
- 34 mm
1x300 mm²
49595- Outer Ø
- 34,4 mm
- Weight
- 3,16 kg/m
- Min. Hi
- 38 mm
Min. Hi carrier = outer diameter + 10% clearance, the smallest inner height of the cable carrier for this cable. Open datasheets at the manufacturer.
Copper surcharge
Today's copper surcharge
Flexible cables carry a copper surcharge per metre, depending on the copper weight and the copper price of the day. Choose a variant and the number of metres, and you see the surcharge with the quotation we use.
You will hear the price of the cable itself with your request, together with the stock.
Copper surcharge POWER ONE 1000 TPE 1kV
IndicativeFetching today's quotation…
You request price and stock with one click.
Compare
Need something heavier or lighter?
All stroomkabels side by side. Choose the lightest version that meets your cycles and travel length.
| Series | Sheath | Shielding | Cycles up to | Travel length up to | Variants |
|---|---|---|---|---|---|
| POWER 400 1kV | PVC | Unshielded | 4 million | 100 m | 30 |
| POWER 400 C 1kV | PVC | Shielded | 4 million | 100 m | 15 |
| POWER 700 1kV | PUR | Unshielded | 7 million | 500 m | 45 |
| POWER 700 C 1kV | PUR | Shielded | 7 million | 500 m | 30 |
| POWER 1000 TPE 1kV | TPE | Unshielded | 10 million | 1000 m | 18 |
| POWER 1000 C TPE 1kV | TPE | Shielded | 10 million | 1000 m | 12 |
| POWER ONE 700 1kV | PUR | Unshielded | 7 million | 500 m | 24 |
| POWER ONE 700 C 1kV | PUR | Shielded | 7 million | 500 m | 16 |
| POWER ONE 700 PE | PUR | Unshielded | 7 million | 500 m | 15 |
| POWER ONE 1000 TPE 1kV this | TPE | Unshielded | 10 million | 1000 m | 15 |
| POWER ONE 1000 C TPE 1kV | TPE | Shielded | 10 million | 1000 m | 14 |
Frequently asked questions
Questions about the POWER ONE 1000 TPE 1kV
Other series
More power cables
Contact
Cable and carrier
right first time.
Send your cable list. We choose the cables and the carrier, and supply them fully assembled if desired.
- Phone+31 88 002 3500
- E-mailverkoop@wisman-techniek.nl
- AvailableMon–Fri 08:30–17:00





11 specialists in Ruurlo
You speak directly to someone who knows.