Split cable glands.Connector on, cable through.
An ordinary cable gland needs a cable without a plug. A split cable gland opens up: you place the pre-assembled cable in it, close the gland and screw it into a standard metric hole. No soldering, no new connector, no risk of errors.

Choose the brand
Range
8 series in the range
From Icotek. Click a series for the specifications, versions and price by email.

KVT-ER
5 var.Split cable gland for cables with connectors, M25–M63. IP66 / IP68, cable Ø 1–35 mm.
Cable Ø 1–35 mm · IP66 / IP68

KVT
20 var.Split cable gland for cables with connectors, M20–M63. IP54.
IP54 · UL Type 12

KVT-W90
6 var.Split cable gland 90° for cables with connectors, M32/M50. IP54.
IP54 · M32–M50

KVT-SNAP
4 var.Split cable gland for snap-in mounting, for cables with connectors, for cut-outs M32–M63. IP54.
IP54 · M32–M63

KVT 80
4 var.Split cable gland for cables with connectors, suitable for cut-out M80. IP54.
IP54 · UL Type 12

DB
4 var.360° split cable entry system, for cables with and without connectors, M32–M75. IP54, cable Ø 1–15 mm.
Cable Ø 1–15 mm · IP54

QVT
6 var.Compact split cable gland for cables with connectors, M16–M50. IP54.
IP54 · M16–M50

QVT-CLICK
8 var.Split cable gland for snap-in mounting, for cables with connectors, for cut-outs M16–M50. IP54.
IP54 · M16–M50
About the product group · Icotek
Split cable glands
- For
- Cables with and without pre-assembled connector
- Assembly
- In a metric hole, split housing
- Variants
- Straight, 90° and with click system
- Cables
- One or several per gland via grommets
Split cable glands combine the shape of a classic gland with the freedom of a split system. The housing consists of two halves; entry grommets clamp inside that close precisely around the cable. This lets cables with connectors pass through an M20 to M63 opening without having to remove the plug.
From Icotek we supply the KVT family: the KVT for M20 to M63, the KVT-ER up to IP66/IP68 for M25 to M63, the right-angled KVT-W90, the snap-in KVT-SNAP, the KVT 80 for an M80 hole, the compact QVT and QVT-CLICK from M16, and the DB for 360° cable entry. The cables are fitted with a KT cable grommet that closes tightly around the cable.
When
When do you choose split cable glands?
- 01Cables are already assembled
- Sensor, bus and motor cables come with a connector. You don't want to cut them through or reconnect them.
- 02There is already a round hole
- The cabinet or machine has metric holes. A split cable gland fits without a new cut-out.
- 03Few cables per opening
- One to a few cables per entry. For large bundles a frame or entry plate makes more sense.
- 04Service has to be quick
- Replace a cable without dismantling the whole entry: open, swap, close.
How to choose
From cable list to the right model
Send your cable list. We choose the model and size and check that everything fits.
Send your cable list01Count the cables and measure the diameters
The outer diameter of each cable. This determines which entry grommets you need and how many fit in one gland.
02Determine the hole size
Existing bore (M20, M25, M32, M40, M50, M63) or free choice. The opening diameter is in the table per model.
03Straight or right-angled
With little space behind the cabinet wall or a cable that has to go straight down: choose a 90° version.
Application
Used in
- Switch cabinets and control cabinets
- Machine panels and control cabinets
- Robot cells with sensor and bus cables
- Retrofit of existing cabinets with round holes
What Wisman does for you
- Advice on your cabinet: which entry, which size, how many cables
- One point of contact from cable carrier to control cabinet wall
- Datasheet and article numbers per model, on the site or by e-mail
- Matched to your cable package from the configurator or ChainLogic
Let the planner work it out
Cables with plug through a round hole? For each cable the planner selects a split entry grommet in the right metric size, and checks whether the plug fits through the hole.
Open the cable entry plannerCompare
All series side by side
Brand, protection rating, range and mounting per series. Unsure between two? Send us your cable list and we will choose.
- DESPREDDetas Ultra25,5–63,5 mm
- DESPRED 50-90Detas Ultra50.5 mm · Metric
- DESCLICKDetas Ultra20.5–32.5 mm · Metric
- OSFDetas Ultra16.5–32.5 mm · Metric
- OSF 40Detas Ultra40.5 mm · Metric
- OSF50 & OSF63Detas Ultra50.5–63.5 mm · Metric
- OSF 90Detas Ultra16.5–32.5 mm · Metric
- KVT-ERIcotekIP66 / IP68 · 1–35 mm · Metrische uitsparingen M25, M32, M50, M63
- KVTIcotekIP54 · M20 - M63
- KVT-W90IcotekIP54 · M32 / M50
- KVT-SNAPIcotekIP54 · Uitsparingen M32 - M63
- KVT 80IcotekIP54 · Uitsparing M80; wanddikte 1,5 tot 10 mm
- DBIcotekIP54 · 1–15 mm · Metrische uitsparingen M32 tot M75
- QVTIcotekIP54 · M16 - M50
- QVT-CLICKIcotekIP54 · Uitsparingen M16 - M50; wanddikte 1,5–2,5 mm …
Article number
Search directly by article number
Do you already know which model you are looking for? Enter the model or article number and request a price straight away.
KVT-ER5 variants
View the series| Model | Article number | View |
|---|---|---|
| KVT-ER-25 | ||
| KVT-ER-32 | ||
| KVT-ER-50-2 | ||
| KVT-ER-63-4 | ||
| KVT-ER-63-1 |
KVT5 variants
View the series| Model | Article number | View |
|---|---|---|
| KVT 20 gy | ||
| KVT 20 bk | ||
| KVT 25 gy | ||
| KVT 25 bk | ||
| KVT 32 gy |
10 of 57 variants · click a variant to view it
In practice
Split cable glands in practice

Featured project
Heavy-duty TKHP cable carrier for container cranes at ECT Euromax Rotterdam
On the container cranes of ECT Euromax in Rotterdam, we replaced the cable management with TKHP cable carriers for long travel lengths, prepared in the workshop and installed within a tight time slot.
- Customer
- ECT Euromax
- Location
- Rotterdam
- Sector
- Cranes & ports
- Solution
- Cable carriers
- Environment
- Outdoors, salty sea air and strong winds
- Assembly
- Prepared in the workshop, installed within a tight time slot
More about split cable glands
Practical articles from our specialists: choosing, calculating, installing and maintaining. No sales talk.

Written by
Olaf Otten
Frequently asked questions
About split cable glands
Cable entries
Other solutions
Split cable glands
Not sure which
does the model fit?
Send your cable list or a photo of the cabinet. A specialist advises within 1 working day.
- Phone+31 88 002 3500
- E-mailverkoop@wisman-techniek.nl
- AvailableMon–Fri 08:30–17:00





11 specialists in Ruurlo
You speak directly to someone who knows.




