Servo cable and motor cable for the cable carrier
Power and feedback,shielded in motion.
A moving servo motor needs power and feedback: two cables, or one hybrid. In the cable carrier they must bend millions of times without the shield failing.

Explanation
What a servo cable must be able to do
- Series on this page
- 11
- Variants
- 148
- Cycles up to
- 10 million
- Travel length up to
- 1000 m
A servo cable carries power from the drive to the motor. Feedback from the encoder or resolver runs via a separate data cable, or within a hybrid system cable. If the motor moves with the machine, those cables run through the cable carrier.
In TRAXLINE you find power supply among the power cables: POWER is multi-core, POWER ONE is single-core for large cross-sections. Both come unshielded and shielded; the C in the name stands for the shielded version. Feedback is among the data cables with twisted pairs (TPi), single or double shielded.
If you want fewer cables in the carrier, the hybrid system cables SYSTEM S and SYSTEM M combine power and signal in one shielded jacket. They are specified up to 5 million movement cycles and 50 m travel. If you need more, choose separate cables from class 700 or 1000.
On a frequency or servo drive, shielding is a requirement: the motor cable emits interference and the encoder cable is sensitive to it. Connect the shield over the full circumference and separate power and signal in the cable carrier with a separator.
From the cable data
Power, hybrid and feedback
The shielded power cables, the hybrid system cables and the twisted-pair data cables from the cable data. Per series the limits for cycles and travel.
POWER 400 C 1kV
- Type
- Power cables
- Sheath
- PVC
- Shielding
- Shielded
- Cycles
- 4 million
- Travel length
- 100 m
- Ø
- 10,4–33,9 mm
POWER 700 C 1kV
- Type
- Power cables
- Sheath
- PUR
- Shielding
- Shielded
- Cycles
- 7 million
- Travel length
- 500 m
- Ø
- 9,2–66 mm
POWER 1000 C TPE 1kV
- Type
- Power cables
- Sheath
- TPE
- Shielding
- Shielded
- Cycles
- 10 million
- Travel length
- 1000 m
- Ø
- 13,7–62,5 mm
POWER ONE 700 C 1kV
- Type
- Power cables
- Sheath
- PUR
- Shielding
- Shielded
- Cycles
- 7 million
- Travel length
- 500 m
- Ø
- 6,1–35,4 mm
POWER ONE 1000 C TPE 1kV
- Type
- Power cables
- Sheath
- TPE
- Shielding
- Shielded
- Cycles
- 10 million
- Travel length
- 1000 m
- Ø
- 7,4–35,4 mm
DATA 700 TPi C
- Type
- Data cables
- Sheath
- PUR
- Shielding
- Shielded
- Cycles
- 7 million
- Travel length
- 200 m
- Ø
- 6,5–18,2 mm
DATA 700 TPi CD
- Type
- Data cables
- Sheath
- PUR
- Shielding
- Double shielded
- Cycles
- 7 million
- Travel length
- 200 m
- Ø
- 13,1–27,5 mm
DATA 700 TPi CD 1kV
- Type
- Data cables
- Sheath
- PUR
- Shielding
- Double shielded
- Cycles
- 7 million
- Travel length
- 200 m
- Ø
- 19,4–37,5 mm
DATA 1000 TPi C TPE
- Type
- Data cables
- Sheath
- TPE
- Shielding
- Shielded
- Cycles
- 10 million
- Travel length
- 400 m
- Ø
- 6,4–17,8 mm
SYSTEM S 700 C
- Type
- System cables
- Sheath
- PUR
- Shielding
- Shielded
- Cycles
- 5 million
- Travel length
- 50 m
- Ø
- on request
SYSTEM M 700 C
- Type
- System cables
- Sheath
- PUR
- Shielding
- Double shielded
- Cycles
- 5 million
- Travel length
- 50 m
- Ø
- on request
Choose
How to choose the servo cable
01Cores and cross-section
Choose the cross-section by current and length. G in the designation means with a green-yellow protective conductor: 4G1.5 is four cores of 1.5 mm² with earth.
02Shielded or not
On a frequency or servo drive always shielded: the C version or a hybrid system cable.
03Class by cycles and travel
POWER 400 goes up to 4 million cycles and 100 m, 700 up to 7 million and 500 m, 1000 up to 10 million and 1000 m.
04Sheath
PVC in class 400, PUR in 700, TPE in 1000. With oil, coolant or heavy wear, PUR or TPE.
05Outer diameter
The inner height of the cable carrier is at least the diameter × 1.1. The radius is at least 7.5 × the diameter of the thickest cable.
06Layout
Power and signal separated by a separator, not crossed and with space around each cable.
Read on
Practical articles from our specialists: choosing, calculating, installing and maintaining. No sales talk.


Written by
Bas Egberink, Olaf Otten
- Choose & calculate · 10 minShielded cable in the cable carrier: when and how?
- Cable entries · 10 minEMC shielding of cables: what it is and how to connect it
- Choose & calculate · 8 minFlexible and hybrid cables for machines: what to choose?
- Choose & calculate · 10 minPUR or PVC cable in the cable carrier: which jacket?
Frequently asked questions
Questions about servo and motor cable
Cables by application
Other applications
Contact
Cables and carrier
right first time.
Send your cable list or machine. We choose the cables and the carrier, and supply them fully assembled if desired.
- Phone+31 88 002 3500
- E-mailverkoop@wisman-techniek.nl
- AvailableMon–Fri 08:30–17:00





11 specialists in Ruurlo
You speak directly to someone who knows.