Servo cable and motor cable for the cable carrier

Power and feedback,shielded in motion.

A moving servo motor needs power and feedback: two cables, or one hybrid. In the cable carrier they must bend millions of times without the shield failing.

two cable carriers with cables on a machine

Explanation

What a servo cable must be able to do

Series on this page
11
Variants
148
Cycles up to
10 million
Travel length up to
1000 m

A servo cable carries power from the drive to the motor. Feedback from the encoder or resolver runs via a separate data cable, or within a hybrid system cable. If the motor moves with the machine, those cables run through the cable carrier.

In TRAXLINE you find power supply among the power cables: POWER is multi-core, POWER ONE is single-core for large cross-sections. Both come unshielded and shielded; the C in the name stands for the shielded version. Feedback is among the data cables with twisted pairs (TPi), single or double shielded.

If you want fewer cables in the carrier, the hybrid system cables SYSTEM S and SYSTEM M combine power and signal in one shielded jacket. They are specified up to 5 million movement cycles and 50 m travel. If you need more, choose separate cables from class 700 or 1000.

On a frequency or servo drive, shielding is a requirement: the motor cable emits interference and the encoder cable is sensitive to it. Connect the shield over the full circumference and separate power and signal in the cable carrier with a separator.

From the cable data

Power, hybrid and feedback

The shielded power cables, the hybrid system cables and the twisted-pair data cables from the cable data. Per series the limits for cycles and travel.

  • POWER 400 C 1kV

    Type
    Power cables
    Sheath
    PVC
    Shielding
    Shielded
    Cycles
    4 million
    Travel length
    100 m
    Ø
    10,4–33,9 mm
  • POWER 700 C 1kV

    Type
    Power cables
    Sheath
    PUR
    Shielding
    Shielded
    Cycles
    7 million
    Travel length
    500 m
    Ø
    9,2–66 mm
  • POWER 1000 C TPE 1kV

    Type
    Power cables
    Sheath
    TPE
    Shielding
    Shielded
    Cycles
    10 million
    Travel length
    1000 m
    Ø
    13,7–62,5 mm
  • POWER ONE 700 C 1kV

    Type
    Power cables
    Sheath
    PUR
    Shielding
    Shielded
    Cycles
    7 million
    Travel length
    500 m
    Ø
    6,1–35,4 mm
  • POWER ONE 1000 C TPE 1kV

    Type
    Power cables
    Sheath
    TPE
    Shielding
    Shielded
    Cycles
    10 million
    Travel length
    1000 m
    Ø
    7,4–35,4 mm
  • DATA 700 TPi C

    Type
    Data cables
    Sheath
    PUR
    Shielding
    Shielded
    Cycles
    7 million
    Travel length
    200 m
    Ø
    6,5–18,2 mm
  • DATA 700 TPi CD

    Type
    Data cables
    Sheath
    PUR
    Shielding
    Double shielded
    Cycles
    7 million
    Travel length
    200 m
    Ø
    13,1–27,5 mm
  • DATA 700 TPi CD 1kV

    Type
    Data cables
    Sheath
    PUR
    Shielding
    Double shielded
    Cycles
    7 million
    Travel length
    200 m
    Ø
    19,4–37,5 mm
  • DATA 1000 TPi C TPE

    Type
    Data cables
    Sheath
    TPE
    Shielding
    Shielded
    Cycles
    10 million
    Travel length
    400 m
    Ø
    6,4–17,8 mm
  • SYSTEM S 700 C

    Type
    System cables
    Sheath
    PUR
    Shielding
    Shielded
    Cycles
    5 million
    Travel length
    50 m
    Ø
    on request
  • SYSTEM M 700 C

    Type
    System cables
    Sheath
    PUR
    Shielding
    Double shielded
    Cycles
    5 million
    Travel length
    50 m
    Ø
    on request

Choose

How to choose the servo cable

  1. 01Cores and cross-section

    Choose the cross-section by current and length. G in the designation means with a green-yellow protective conductor: 4G1.5 is four cores of 1.5 mm² with earth.

  2. 02Shielded or not

    On a frequency or servo drive always shielded: the C version or a hybrid system cable.

  3. 03Class by cycles and travel

    POWER 400 goes up to 4 million cycles and 100 m, 700 up to 7 million and 500 m, 1000 up to 10 million and 1000 m.

  4. 04Sheath

    PVC in class 400, PUR in 700, TPE in 1000. With oil, coolant or heavy wear, PUR or TPE.

  5. 05Outer diameter

    The inner height of the cable carrier is at least the diameter × 1.1. The radius is at least 7.5 × the diameter of the thickest cable.

  6. 06Layout

    Power and signal separated by a separator, not crossed and with space around each cable.

Frequently asked questions

Questions about servo and motor cable

Cables by application

Other applications

All applications

Contact

Cables and carrier
right first time.

Send your cable list or machine. We choose the cables and the carrier, and supply them fully assembled if desired.

Call a specialist
Grego ErnstTieme ErnstOlaf OttenBas EgberinkDaan van Weeghel

11 specialists in Ruurlo
You speak directly to someone who knows.

Prefer a quick call?

Leave your number and a specialist will call you back.