Cable entry plates.The economical alternative to cable glands.

A cable entry plate replaces a row of glands with one plate with membranes. You pierce the membrane, push the cable through, and the second membrane provides strain relief and sealing. Faster to fit and more economical than separate glands.

KEL-DPF-OD from Icotek

Range

18 series in the range

From Icotek. Click a series for the specifications, versions and price by email.

KEL-DPF-OD from Icotek

KEL-DPF-OD

6 var.

Pyramid-shaped cable grommet for extreme conditions, for single cables up to 60 mm, M25 to M75. IP66 / IP68.

Cable Ø 3–60 mm · IP66 / IP68

KEL-DPU-OD from Icotek

KEL-DPU-OD

8 var.

Multi-range membrane cable entry plates for extreme conditions, snap-in. IP66 / IP68, cable Ø 3.2–20.5 mm.

Cable Ø 3.2–20.5 mm · IP66 / IP68

KEL-DPU from Icotek

KEL-DPU

16 var.

Multi-range membrane cable entry plates with high strain relief, snap-in. IP66 / IP68, cable Ø 3.2–20.5 mm.

Cable Ø 3.2–20.5 mm · IP66 / IP68

KEL-DPU-HD from Icotek

KEL-DPU-HD

8 var.

Hygienic multi-range membrane cable entry plates with high strain relief, snap-in. IP66 / IP68, cable Ø 3.2–20.5 mm.

Cable Ø 3.2–20.5 mm · IP66 / IP68

KEL-DPZ round from Icotek

KEL-DPZ round

30 var.

Round multi-range membrane cable entry plates with metric thread M25–M63. IP66 / IP68, cable Ø 1,5–22 mm.

Cable Ø 1,5–22 mm · IP66 / IP68

KEL-DPZ-CLICK from Icotek

KEL-DPZ-CLICK

15 var.

Snap-in membrane cable entry plates with metric thread M25–M63. IP66 / IP68, cable Ø 1,5–22 mm.

Cable Ø 1,5–22 mm · IP66 / IP68

KEL-DPZ-HD round from Icotek

KEL-DPZ-HD round

14 var.

Round hygienic multi-range membrane cable entry plates with metric thread M25–M63. IP66 / IP68, cable Ø 3,2–22,2 mm.

Cable Ø 3.2–22.2 mm · IP66 / IP68

KEL-DPZ from Icotek

KEL-DPZ

54 var.

Multi-range membrane cable entry plates with high cable density. IP66, cable Ø 1,5–22 mm.

Cable Ø 1.5–22 mm · IP66

KEL-DPR from Icotek

KEL-DPR

5 var.

Multi-range membrane cable entry plates with high cable density. IP65, cable Ø 1–16,1 mm.

Cable Ø 1–16.1 mm · IP65

UT-DT from Icotek

UT-DT

5 var.

U-shaped membrane cable entry grommet for cables without connectors, tool-free installation. IP54, cable Ø 1–11 mm.

Cable Ø 1–11 mm · IP54

KEL-DP from Icotek

KEL-DP

64 var.

Multi-range membrane cable entry plates, snap-in, with high cable density. IP64.

IP64 · UL Type 12

KEL-DP round from Icotek

KEL-DP round

63 var.

Multi-range membrane cable entry plates, snap-in for metric cut-outs M12–M50. IP65.

IP65 · UL Type 12

KEL-SCDP-TR from Icotek

KEL-SCDP-TR

6 var.

Multi-range cable entry grommets with metric thread M25–M63, for single cables with diameters up to 52 mm. IP65.

Cable Ø up to 52 mm · IP65

KEL-SCDP from Icotek

KEL-SCDP

14 var.

Multi-range cable entry grommets, snap-in, for single cables with diameters up to 36 mm. IP65.

Cable Ø up to 36 mm · IP65

KEL-DPFR from Icotek

KEL-DPFR

14 var.

Multi-range cable entry plate with pyramid-shaped membranes, for cables with diameters up to 28 mm. IP66.

Cable Ø 3–28 mm · IP66

KEL-DPF from Icotek

KEL-DPF

14 var.

Pyramid-shaped grommets for single cables with diameters up to 70 mm, M25–M85. IP66 / IP68.

Cable Ø 3–70 mm · IP66 / IP68

KEL-ULTRA flex from Icotek

KEL-ULTRA flex

2 var.

Pyramid cable entry grommets for single cables with diameters up to 115 mm. IP66.

Cable Ø 25–115 mm · IP66

KEL-JUMBO flex from Icotek

KEL-JUMBO flex

2 var.

Pyramid cable entry grommets for single cables with diameters up to 68 mm. IP54.

Cable Ø 27–68 mm · IP54

About the product group · Icotek

Cable entry plates

For
Cables without connector (PDP: with connector)
Operation
Double membrane: seal + strain relief
Shapes
Rectangular, square, compact and metric round
Hygiene
Clean version made of FDA-approved material

Each opening in the plate has two membranes. The front membrane is pierced and closes around the cable; the second membrane clamps the cable and gives extra strain relief and a high IP rating. Nothing needs to be tightened.

From Icotek we supply the KEL-DP family: KEL-DPU and KEL-DPZ up to IP66/IP68, round and snap-in plates for M25 to M63, hygienic HD plates for food, and pyramid grommets for a single thick cable: KEL-DPF up to 70 mm and KEL-ULTRA flex up to 115 mm.

When

When do you choose cable entry plates?

01Many cables without connector
Up to more than a hundred thin cables through one plate, instead of as many glands.
02Speed in the workshop
Pierce and push through. No nuts, no tools per cable.
03Budget matters
More economical than individual glands, while keeping the seal and strain relief.
04Food & pharma
The Clean plates have rounded shapes without dirt traps and are easy to clean.

How to choose

From cable list to the right model

Send your cable list. We choose the model and size and check that everything fits.

Send your cable list
  1. 01Cut-out or round hole

    Rectangular plates fit a standard cut-out; the M versions fit metric holes from M20 to M63.

  2. 02Count cables per diameter class

    Each plate has a fixed layout of openings per diameter range. The table shows the number and Ø per model.

  3. 03Choose colour and material

    Grey or black, and the Clean version for hygienic environments.

Application

Used in

  • Switch cabinets in series production
  • Food and pharmaceutical machinery
  • Distribution boxes and terminal boxes
  • Machine building with many sensor cables

What Wisman does for you

  • Advice on your cabinet: which entry, which size, how many cables
  • One point of contact from cable carrier to control cabinet wall
  • Datasheet and article numbers per model, on the site or by e-mail
  • Matched to your cable package from the configurator or ChainLogic

Let the planner work it out

Which plate, and which cable in which opening? Fill in your cable list. The planner chooses the plates with the fewest cut-outs and shows what remains free, with article numbers.

Open the cable entry planner

Compare

All series side by side

Brand, protection rating, range and mounting per series. Unsure between two? Send us your cable list and we will choose.

Article number

Search directly by article number

Do you already know which model you are looking for? Enter the model or article number and request a price straight away.

KEL-DPF-OD6 variants

View the series
ModelArticle numberView
KEL-DPF 25 OD
KEL-DPF 32 OD
KEL-DPF 40 OD
KEL-DPF 50 OD
KEL-DPF 63 OD
KEL-DPF 75 OD

KEL-DPU-OD4 variants

View the series
ModelArticle numberView
KEL-DPU 24-13 OD
KEL-DPU 24-14 OD
KEL-DPU 24-16 OD
KEL-DPU 24-16-1 OD

10 of 340 variants · click a variant to view it

In practice

Cable entry plates in practice

All projects
Heavy-duty cable carrier in the guide trough of a container crane

Featured project

Heavy-duty TKHP cable carrier for container cranes at ECT Euromax Rotterdam

On the container cranes of ECT Euromax in Rotterdam, we replaced the cable management with TKHP cable carriers for long travel lengths, prepared in the workshop and installed within a tight time slot.

Customer
ECT Euromax
Location
Rotterdam
Sector
Cranes & ports
Solution
Cable carriers
Environment
Outdoors, salty sea air and strong winds
Assembly
Prepared in the workshop, installed within a tight time slot
Read the project

More about cable entry plates

Practical articles from our specialists: choosing, calculating, installing and maintaining. No sales talk.

Written by
Olaf Otten

Frequently asked questions

About cable entry plates

Cable entries

Other solutions

All cable entries

Cable entry plates

Not sure which
does the model fit?

Send your cable list or a photo of the cabinet. A specialist advises within 1 working day.

Call a specialist
Grego ErnstTieme ErnstOlaf OttenBas EgberinkDaan van Weeghel

11 specialists in Ruurlo