Cable carrier for a gantry with X and Y axis: build the cable package per axis, choose type and radius and calculate the cables. With worked example.

Bas EgberinkCable Carriers Specialist

26 Nov 2026 · 14 min read

Short answer

A gantry with an X and a Y axis gets a separate cable carrier for each axis. The Y carrier sits on the carriage of the X axis, so the X carrier carries everything that goes to the Y axis and the head, plus the lines for the X carriage itself. So calculate from the head to the cabinet: first the package of the Y carrier, then the larger package of the X carrier. Each carrier gets its own inner dimensions, radius and length, and each cable a length that runs through both carriers.

Cable carrier for gantries: X and Y axis

A gantry with an X and a Y axis gets a separate cable carrier for each axis. The Y carrier sits on the carriage of the X axis and therefore moves with it. As a result, the X carrier carries not only the lines for the X carriage, but also everything that goes to the Y axis and the head. If you start with the X axis, you often forget part of that package. So start at the head and work back to the cabinet.

Below you can read how to build the package per axis, how to choose the two carriers and how to determine the cable length through both carriers. With a worked example.

How does the cable package run through a gantry with X and Y axis?

On a typical gantry, the lines run from the cabinet to the tool in three sections:

  1. (01)From the cabinet to the fixed point of the X carrier. This section is stationary, in a duct or cable tray along the machine.
  2. (02)Through the X carrier to the X carriage. On the carriage, the lines run to the fixed point of the Y carrier. That fixed point is on the carriage and therefore moves with the X axis.
  3. (03)Through the Y carrier to the Y slide and the head. There the lines go to the motors, sensors and valves on the slide or the Z axis.

Every carrier has a fixed point and a driver. On the X carrier, the fixed point is on the frame and the driver is attached to the X carriage. On the Y carrier, both are on the X carriage and the Y slide. How to choose the fixed point per axis is explained in fixed point of a cable carrier.

If the gantry also has a Z axis with a long vertical stroke, a third carrier may be added there. The principle stays the same: each axis adds its lines to the carrier of the axis below it.

Why start at the head of the gantry?

Because the package per axis grows the closer you get to the cabinet. The Y carrier only carries what is on the Y slide and the head. The X carrier carries that entire package, plus what the X carriage itself needs.

Make a list per axis:

  • Y carrier: the motor cable of the Y axis if that motor sits on the slide, the cables and hoses for the Z axis and the tool, sensors on the slide.
  • X carrier: everything on the Y carrier list, plus the motor cable of the X axis if that motor sits on the carriage, sensors on the carriage and possibly the cable to a terminal box on the carriage.

Check where the motors are. A motor that sits on the frame and drives the carriage with a belt does not need to go through the carrier. A motor on the carriage does. That sometimes saves a thick servo cable and with it a smaller radius.

Worked example: cable carrier for the X and Y axis

A gantry has an X axis with 3000 mm travel length and a Y axis with 1200 mm travel length. Both motors sit on the moving parts. The Z axis and a gripper sit on the Y slide. We calculate with the rules the configurator also uses: cable × 1.10 and hose × 1.20 for the space, radius 7.5 × the thickest cable and the fixed point in the middle.

Y carrier package: two 10 mm servo cables (Y motor and Z motor), a 6 mm sensor cable and two 6 mm pneumatic hoses.

LineDiameterEffective
Servo cable Y (1×)10 mm11,0 mm
Servo cable Z (1×)10 mm11,0 mm
Sensor cable (1×)6 mm6,6 mm
Pneumatic hose (2×)6 mm7.2 mm per hose
  1. (01)Inner height: at least 11.0 mm.
  2. (02)Inner width: 11.0 + 11.0 + 6.6 + 2 × 7.2 = 43.0 mm. With one 2 mm divider between cables and hoses, that is 45 mm.
  3. (03)Radius: 7.5 × 10 mm = 75 mm.
  4. (04)Type: a UNIFLEX Advanced UA1250 has 17.5 mm inner height, 50 mm inner width and a radius of 75 mm. Self-supporting, it reaches a travel length of 1.6 m, enough for 1200 mm.
  5. (05)Length: 1200 / 2 + π × 75 + 2 × 25 = 885.6 mm. Rounded to whole links of 25 mm: 36 links, 900 mm.

X carrier package: everything from the Y carrier plus the servo cable of the X motor, also 10 mm.

  1. (01)Inner width: 3 × 11.0 + 6.6 + 2 × 7.2 = 54.0 mm, with divider 56 mm.
  2. (02)Radius: the thickest cable is still 10 mm, so at least 75 mm.
  3. (03)Type: a UA1320 with 65 mm inner width fits in size, but is self-supporting only up to 2.9 m. That is just too short for 3 m travel length. The UA1455 reaches 4.8 m. It has an inner width of 58 mm and the next radius above 75 mm is 95 mm.
  4. (04)Length: 3000 / 2 + π × 95 + 2 × 45.5 = 1889.5 mm. Rounded to whole links of 45.5 mm: 42 links, 1911 mm.

Two things stand out. The X carrier does not get bigger because of the inner dimensions, but because of the travel length: the smaller type cannot span the 3 metres self-supporting. And with 56 of the 58 mm, the UA1455 is now almost full. If another cable is added later, 78 mm inner width is the safer choice. Check the length yourself with calculate the length of your cable carrier.

Calculate it yourselfCalculate cable carrier lengthLength and number of links from travel length and radiusCalculate it

How long is a cable that runs through two cable carriers?

Add up all sections. For the servo cable of the Z axis in the example:

SectionLength
Cabinet to fixed point of X carrier1,5 m
X carrier1,91 m
Across the X carriage to the fixed point of the Y carrier0,5 m
Y carrier0,90 m
From the Y slide to the Z motor0,6 m
Reserve, 0.3 m per end0,6 m
Total6.01 m

Rounded up to a tenth of a metre, you order 6.1 metres. The section across the X carriage is often forgotten. Measure it on the drawing of the carriage, following the route from the driver of the X carrier to the fixed point of the Y carrier. How to calculate per cable is explained in detail in calculating cable length in a cable carrier.

Do you run the cables in one piece or with a connection on the carriage?

Both are common. A cable that runs in one piece from the cabinet to the head has no extra connection that can come loose or cause interference. A connection on the X carriage, with a terminal box or connectors, makes replacement easier: if the cable breaks in the Y carrier, you only replace that section.

A few points to weigh up:

  • Wear differs per axis. The carrier with the most strokes per day or the tightest radius wears first. With a connection on the carriage, you only replace that cable.
  • Signal and data. Every connection in a shielded cable must properly carry the shield through. For encoder and bus cables, one continuous piece is often the most reliable choice.
  • Space on the carriage. A terminal box must fit and must not obstruct the movement of the Y carrier.

In both cases, choose cables that are made for moving use in a cable carrier, with a bending radius that suits the radius of each carrier. View the flexible cables by type and class.

How do you secure the cables between the two cable carriers?

Each carrier gets its own strain relief at both ends. So also at the driver of the X carrier and the fixed point of the Y carrier, which are both on the X carriage. Without a clamp at that point, the movement of one carrier pulls on the cables in the other. The cables then slowly slide through and get trapped in the bend. Read more about the principle in what is strain relief.

Route the cables on the carriage along a fixed path, preferably in a duct or on a cable tray, and let them run straight after the clamp before they bend away. Keep the layout the same in both carriers: the cable on the left in the X carrier is also on the left in the Y carrier. Then no cables cross on the carriage. Draw the cross-section of each carrier in ChainLogic, with cables, hoses and dividers in place.

Calculate it yourselfChainLogicLay out cables, hoses and dividers in the cross-sectionOpen ChainLogic

How do you mount the cable carrier of the Y axis?

The X carrier is usually mounted lying on the frame or standing next to the machine, as on any linear axis. The Y carrier has less space. It sits on the carriage and must stay within the installation height of the gantry. There are three common arrangements:

  • Standing on the carriage: the bend facing up or down. This is the simplest arrangement, but costs installation height.
  • Lying on the carriage: the carrier lies on its side. This saves height, but the carrier needs support. Read what to look out for in mounting a cable carrier on its side.
  • With the bend facing down: the carrier is upside down, for example under a beam above the working area. Always have this arrangement checked, because not every type and every package is suitable for it.

For standing mounting, calculate the installation height. It is roughly twice the radius plus the height of the link. In the example, that is 2 × 75 + 23 = 173 mm for the UA1250. For the UA1455 on the X axis it is 2 × 95 + 36 = 226 mm.

Which cable carrier suits a gantry?

Gantries often move fast and accelerate hard, and the Y carrier is extra mass that the X axis drags along. So choose a light carrier for the Y axis in the smallest size that fits. For most gantries, the UNIFLEX Advanced is a good all-round choice. With the QuickTrax® you press cables into elastic lamellae, which works quickly on a small Y carrier. For a small package to the Z axis or the tool, the compact MONO is suitable. How speed and acceleration count is explained in cable carrier at high speed and acceleration.

If it is a robot arm rather than a gantry, a dresspack is usually the better choice.

Enter your cables, hoses and travel length per axis in the cable carrier configurator. Start with the Y axis, then include that package in the X axis. The configurator determines the inner dimensions, radius and length per carrier and shows the types that fit. A Wisman specialist checks both carriers free of charge.

Calculate it yourselfCable carrier configuratorCalculate, select and assemble a cable carrierOpen the cable carrier configurator

Frequently asked questions

Does every axis of a gantry need its own cable carrier?

Yes, every moving axis gets its own carrier. The carrier of the upper axis sits on the carriage of the axis below it and moves with it.

Why is the cable carrier of the X axis larger than that of the Y axis?

Because it also carries all lines for the Y axis and the head, plus those for the X carriage itself. The X axis is often longer as well, so a larger type is needed to span the travel length self-supporting.

Where is the fixed point of the cable carrier on the Y axis?

On the X carriage, usually in the middle of the travel length of the Y axis. This keeps the carrier as short as possible. The fixed point moves with the X axis.

Does a cable between two cable carriers need to be secured?

Yes. Secure the cable at the driver of the lower carrier and at the fixed point of the upper carrier. Otherwise one carrier pulls on the cables in the other.

How do I calculate the cable length on a gantry with two axes?

Add up the route from the cabinet to the first carrier, the length of both carriers, the route across the carriage, the route to the connection point and a reserve at both ends. Round up per cable.

Calculate it yourself

Which cable carrier fits your machine?

Enter two dimensions. The configurator opens with these values and shows the matching series right away. We check your result free of charge.

Not sure? Leave it blank and fill it in in the configurator.

Replacement

Old cable carrier broken
or worn out?

Send the type number, the size or a photo of your current carrier. Within 1 working day you'll hear which replacement fits, what it costs and when it arrives. Also if your carrier is from another brand.

Prefer to search yourself? Find a matching replacement or view all cable carriers from stock.